DC/DC Railway Converter
•
•
Compact metal package
•
EN 50155 approval for railway
applications
•
•
•
•
•
•
•
•
Very high efficiency up to 91%
TEP 160WIR Series, 160 Watt
Ultra wide 4:1 input voltage ranges
9–36, 18–75, 43–160 VDC
No minimum load
Soft start
Adjustable output voltage +10 / -20%
Sense line
UL 62368-1 IEC 62368-1
Remote On/Off input
Under voltage lock-out circuit
3-year product warranty
The TEP 160WIR Series is a family of isolated high performance DC/DC converter modules with ultra-wide 4:1 input voltage ranges which come in a
rugged, sealed industry standard half brick package. A very high efficiency allows full power operation without forced air cooling at 25°C This temperature
can be increased to 40°C with optional mounted heatsink or up to 60°C when
mounted on an iron base plate. The very wide input voltage range and reverse
input voltage protection make these converters interesting solution for battery
operated systems. Typical applications are in telecom/datacom, industry control and railway systems for on board power distribution. These series is available in many optional designs on demand --> see options.
Models
Order Code
Input Voltage
Range
TEP 160-2412WIR
TEP 160-2413WIR
TEP 160-2415WIR
TEP 160-2416WIR
9 - 36 VDC
(24 VDC nom.)
Output Voltage
Output Current
Efficiency
nom. (adjustable)
max.
typ.
12 VDC (9.6 - 13.2 VDC)
12'000 mA
90 %
15 VDC (12.0 - 16.5 VDC)
9'500 mA
91 %
24 VDC (19.2 - 26.4 VDC)
6'000 mA
90 %
28 VDC (22.4 - 30.8 VDC)
5'000 mA
90 %
TEP 160-2418WIR
48 VDC (38.4 - 52.8 VDC)
3'000 mA
90 %
TEP 160-4812WIR
12 VDC (9.6 - 13.2 VDC)
13'000 mA
91 %
15 VDC (12.0 - 16.5 VDC)
10'000 mA
91 %
24 VDC (19.2 - 26.4 VDC)
6'500 mA
91 %
28 VDC (22.4 - 30.8 VDC)
5'500 mA
91 %
48 VDC (38.4 - 52.8 VDC)
3'200 mA
91 %
TEP 160-7212WIR
12 VDC (9.6 - 13.2 VDC)
15'000 mA
90 %
TEP 160-7213WIR
15 VDC (12.0 - 16.5 VDC)
12'000 mA
90 %
24 VDC (19.2 - 26.4 VDC)
7'500 mA
90 %
28 VDC (22.4 - 30.8 VDC)
6'500 mA
90 %
48 VDC (38.4 - 52.8 VDC)
3'800 mA
90 %
TEP 160-4813WIR
TEP 160-4815WIR
TEP 160-4816WIR
18 - 75 VDC
(48 VDC nom.)
TEP 160-4818WIR
TEP 160-7215WIR
TEP 160-7216WIR
TEP 160-7218WIR
www.tracopower.com
43 - 160 VDC
(110 VDC nom.)
October 25, 2023
Page 1 / 5
TEP 160WIR Series, 160 Watt
Options
TEP-HS1
- Optional Heat Sink: www.tracopower.com/products/tep-hs1.pdf
- Optional model with 3.3 VDC / 40'000 mA Output and 9 - 36 VDC Input
- Optional model with 5 VDC / 28'000 mA Output and 9 - 36 VDC Input
- Optional model with 3.3 VDC / 40'000 mA Output and 18 - 75 VDC Input
- Optional model with 5 VDC / 30'000 mA Output and 18 - 75 VDC Input
on demand
- Optional model with 3.3 VDC / 43'000 mA Output and 43 - 160 VDC Input
(backorder with MOQ
non stocking item) - Optional model with 5 VDC / 32'000 mA Output and 43 - 160 VDC Input
- Optional models with Sync pin to synchronize switching frequency of up to 3 units (EMC reason)
- Chassis mount models w/o filter: www.tracopower.com/products/tep160wircm.pdf
- Chassis mount models w/ filter to meet EN 55032 class A: www.tracopower.com/products/tep160wircmf.pdf
- Optional models with inverse Remote On/Off function (passive = off)
Input Specifications
Input Current
- At no load
24 Vin models:
48 Vin models:
110 Vin models:
24 Vin models:
48 Vin models:
110 Vin models:
24 Vin models:
48 Vin models:
110 Vin models:
24 Vin models:
48 Vin models:
110 Vin models:
Surge Voltage
Under Voltage Lockout
Recommended Input Fuse
Input Filter
25 mA typ.
20 mA typ.
10 mA typ.
50 VDC max. (1 s max.)
100 VDC max. (1 s max.)
185 VDC max. (1 s max.)
7.3 VDC min. / 7.7 VDC typ. / 8.1 VDC max.
15.5 VDC min. / 16 VDC typ. / 16.3 VDC max.
33 VDC min. / 34.5 VDC typ. / 36 VDC max.
25'000 mA (fast acting)
15'000 mA (fast acting)
8'000 mA (fast acting)
(The need of an external fuse has to be assessed
in the final application.)
Internal Pi-Type
Output Specifications
Output Voltage Adjustment
Voltage Set Accuracy
Regulation
Ripple and Noise
(20 MHz Bandwidth)
- Input Variation (Vmin - Vmax)
- Load Variation (0 - 100%)
–20% to +10% (By external trim resistor)
See application note: www.tracopower.com/overview/tep160wir
Output power must not exceed rated power!
±1% max.
0.1% max.
0.1% max.
3.3 Vout models: 75 mVp-p max. (w/ 1 µF X7R || 25 µF poscap)
5 Vout models: 75 mVp-p max. (w/ 1 µF X7R || 25 µF poscap)
12 Vout models: 100 mVp-p max. (w/ 1 µF X7R || 25 µF poscap)
15 Vout models: 100 mVp-p max. (w/ 1 µF X7R || 25 µF poscap)
24 Vout models: 200 mVp-p max. (w/ 4.7 µF X7R)
28 Vout models: 200 mVp-p max. (w/ 4.7 µF X7R)
48 Vout models: 300 mVp-p max. (w/ 2.2 µF X7R)
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
October 25, 2023
Page 2 / 5
TEP 160WIR Series, 160 Watt
Capacitive Load
- 24 Vin input
- 48 Vin input
- 110 Vin input
3.3 Vout models:
5 Vout models:
12 Vout models:
15 Vout models:
24 Vout models:
28 Vout models:
48 Vout models:
3.3 Vout models:
5 Vout models:
12 Vout models:
15 Vout models:
24 Vout models:
28 Vout models:
48 Vout models:
3.3 Vout models:
5 Vout models:
12 Vout models:
15 Vout models:
24 Vout models:
28 Vout models:
48 Vout models:
Minimum Load
Temperature Coefficient
Hold-up Time
Start-up Time
Short Circuit Protection
Output Current Limitation
Overvoltage Protection
Transient Response
- Response Time
121'000 µF max.
56'000 µF max.
10'000 µF max.
6'300 µF max.
2'500 µF max.
1'700 µF max.
620 µF max.
121'000 µF max.
60'000 µF max.
10'800 µF max.
6'600 µF max.
2'700 µF max.
1'900 µF max.
660 µF max.
130'000 µF max.
64'000 µF max.
12'500 µF max.
8'000 µF max.
3'100 µF max.
2'300 µF max.
790 µF max.
Not required
±0.02 %/K max.
10 ms min. (acc. to EN 50155 Class S2, see
application note for ext. capacitor calculation:
www.tracopower.com/info/holdup_en50155.pdf)
75 ms typ.
Continuous, Automatic recovery
120 - 150% of Iout max.
115 - 130% of Vout nom.
200 µs typ. / 250 µs max. (25% Load Step)
Safety Specifications
Standards
EN 60950-1
EN 62368-1
IEC 60950-1
IEC 62368-1
UL 60950-1
UL 62368-1
EN 50155
www.tracopower.com/overview/tep160wir
PD 2
OVC II
- IT / Multimedia Equipment
- Railway Applications
- Certification Documents
Pollution Degree
Over Voltage Category
EMC Specifications
EMI Emissions
- Conducted Emissions
- Radiated Emissions
EN 50121-3-2 (EMC for Rolling Stock)
EN 55011 class A (with external filter)
EN 55011 class B (with external filter)
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
EN 55011 class A (with external filter)
EN 55011 class B (with external filter)
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
External filter proposal: www.tracopower.com/overview/tep160wir
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
October 25, 2023
Page 3 / 5
TEP 160WIR Series, 160 Watt
EMS Immunity
- Electrostatic Discharge
- RF Electromagnetic Field
- EFT (Burst) / Surge
- Conducted RF Disturbances
- PF Magnetic Field
EN 50121-3-2 (EMC for Rolling Stock)
Air: EN 61000-4-2, ±8 kV, perf. criteria A
Contact: EN 61000-4-2, ±6 kV, perf. criteria A
EN 61000-4-3, 20 V/m, perf. criteria A
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±2 kV, perf. criteria A
Ext. input component: 24 & 48 Vin models: 2x KY 220 µF
110 Vin models: 2x KXJ 150 µF
EN 61000-4-6, 10 Vrms, perf. criteria A
Continuous: EN 61000-4-8, 100 A/m, perf. criteria A
1 s: EN 61000-4-8, 1000 A/m, perf. criteria A
General Specifications
Relative Humidity
Temperature Ranges
Power Derating
- Operating Temperature
- Case Temperature
- Storage Temperature
- High Temperature
Over Temperature
Protection Switch Off
- Protection Mode
- Measurement Point
Cooling System
Sense Function
Remote Control
- Voltage Controlled Remote
(passive = on)
- Off Idle Input Current
- Remote Pin Input Current
Altitude During Operation
Switching Frequency
Insulation System
Working Voltage (rated)
Isolation Test Voltage
Isolation Resistance
Isolation Capacitance
Reliability
Washing Process
Environment
- Input to Output, 60 s
- Input to Case, 60 s
- Output to Case, 60 s
- Input to Output, 500 VDC
- Input to Output, 100 kHz, 1 V
- Calculated MTBF
- Vibration
- Mechanical Shock
- Thermal Shock
- Flammability
95% max. (non condensing)
–40°C to +75°C
+115°C max.
–55°C to +125°C
Depending on model
See application note: www.tracopower.com/overview/tep160wir
120°C typ. (Automatic recovery at 105°C typ.)
Base-Plate
Natural convection (20 LFM)
10% max. of Vout nom.
(Sense line to be connected to the output either
at the module or at the load under regard of
polarity.)
On: 3.0 to 12 VDC or open circuit
Off: 0 to 1.2 VDC or short circuit
Refers to 'Remote' and '-Vin' Pin
3 mA typ.
-0.5 to 1.0 mA
(Optional models with inverse Remote On/Off
function (passive = off))
2'000 m max. (for reinforced insulation)
5'000 m max. (for functional insulation)
225 - 275 kHz (PWM)
250 kHz typ. (PWM)
Reinforced Insulation
145 VAC (3.3 and 5 Vout models)
185 VAC (48 Vout models)
172 VAC (other output models)
3'000 VAC
1'500 VAC
1'500 VAC
1'000 MΩ min.
2'500 pF max.
350'000 h (MIL-HDBK-217F, ground benign)
According to Cleaning Guideline
www.tracopower.com/info/cleaning.pdf
MIL-STD-810F
EN 61373
MIL-STD-810F
EN 61373
MIL-STD-810F
EN 45545-2
www.tracopower.com/info/en45545-declaration.pdf
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
October 25, 2023
Page 4 / 5
TEP 160WIR Series, 160 Watt
Housing Material
Alu base-plate w. metal case (24 and 48 Vin
models)
Alu base-plate w. plastic case (110 Vin models)
Non-conductive FR4 (UL 94 V-0 rated) (24 and
48 Vin models only)
Silicone (UL 94 V-0 rated)
Copper
Nickel (2 - 3 µm)
Tin (3 - 5 µm), matte
Metal Case (24 and 48 Vin models)
Plastic Case (110 Vin models)
PCB Mount
THD (Through-Hole Device)
Half-Brick
Lead-Free Wave Soldering
260°C / 6 s max.
105 g
Base Material
Potting Material
Pin Material
Pin Foundation Plating
Pin Surface Plating
Housing Type
Mounting Type
Connection Type
Footprint Type
Soldering Profile
Weight
Thermal Impedance
6.1 K/W typ.
4.6 K/W typ. (with Heat Sink)
www.tracopower.com/info/reach-declaration.pdf
REACH SVHC list compliant
REACH Annex XVII compliant
www.tracopower.com/info/rohs-declaration.pdf
Exemptions: 7a, 7c-I
(RoHS exemptions refer to the component
concentration only, not to the overall
concentration in the product (O5A rule).)
2f0f12ea-8c1e-4f75-863d-c66836c1954b
- Case to Ambient
Environmental Compliance - REACH Declaration
- RoHS Declaration
- SCIP Reference Number
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/tep160wir
Outline Dimensions
12.7
(0.5)
61.0 (2.4)
4.8 (0.19)
5.1
(0.2)
0.6
(0.023)
3
10
48.26 (1.9)
4
57.9 (2.28)
Pinout
50.80 (2.0)
2
Pin
1
9
Dimensions in mm (inch)
Tolerances x.x±0.5 (x.xx±0.02)
Tolerances x.xx±0.25 (x.xxx±0.01)
Pin pich tolerances ±0.25 (±0.01)
Pin dimension tolerances ±0.1 (±0.004)
8
7
7.62
(0.3)
17.78 (0.7)
25.4 (1.0)
6
5
The screw1 locked torque
Pin Diameter
1
in (GND)
1.0 mm (0.04 inch)
2
Case
1.0 mm (0.04 inch)
3
Remote On/Off
1.0 mm (0.04 inch)
4
+Vin (Vcc)
1.0 mm (0.04 inch)
5
out
2.0 mm (0.08 inch)
6
ense
1.0 mm (0.04 inch)
BOTTOM VIEW
screw1
4-M3x0.5
(trough hole)
Single
7
Trim
1.0 mm (0.04 inch)
8
+Sense
1.0 mm (0.04 inch)
9
+Vout
2.0 mm (0.08 inch)
10
Sync
(on demand)
1.0 mm (0.04 inch)
24 & 48 Vout models
max. 5.0 kgfcm / 0.49 Nm
110 Vout models
max. 3.5 kgfcm / 0.34 Nm